High-Voltage Outdoor Dry-Type Air-Core Reactor 6KV/10KV/35KV | Hollow Current Limiting Capacitors & Reactor
High-voltage dry-type air-core reactors (6KV, 10KV, 35KV) for reactive power compensation, harmonic suppression, and inrush current limitation. Designed for outdoor substations, electrified railways, and harsh environments.
Product Overview
The XKGKL Series high-voltage outdoor dry-type air-core reactors (6KV, 10KV, 35KV) are engineered to optimize grid efficiency in demanding environments. Paired with hollow current limiting capacitors, these reactors deliver precise reactive power compensation, harmonic suppression, and inrush current protection. Ideal for outdoor substations, renewable energy farms, and industrial grids requiring robust performance under extreme conditions.
Core Features
- ✅ Multi-Voltage Support: Compatible with 6KV, 10KV, and 35KV systems.
- ✅ Outdoor Durability: IP54-rated enclosure for dust, moisture, and corrosion resistance.
- ✅ Reactive Power Compensation: Maintains power factor >0.95 in high-load grids.
- ✅ Harmonic Mitigation: Reduces THD (Total Harmonic Distortion) by up to 40%.
- ✅ Compact & Lightweight: Hollow design saves space and simplifies installation.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | XKGKL-10-3200-0.28 (Customizable for 6KV/35KV) |
| Rated Voltage | 6KV, 10KV, 35KV |
| Rated Current | Up to 5000A (Customizable) |
| Impedance Range | 0.1Ω–5Ω (±5% to ±15% Tolerance) |
| Insulation Class | H-Class (Material) / F-Class (Overall) |
| Noise Level | <65 dB (Outdoor-Optimized) |
| Cooling Method | Natural Convection (Self-Cooling) |
| Temperature Rise Limit | ≤75K (Average) / ≤85K (Hotspot) |
| Lightning Impulse Voltage | 75–200 kV (Peak, Voltage-Dependent) |
| Protection Rating | IP54 (Standard) / IP65 (Optional) |
Applications
- Outdoor Substations: Urban grids, underground facilities, and confined spaces.
- Renewable Energy: Solar/Wind farm grid stabilization and harmonic filtering.
- Heavy Industry: Metallurgy, petrochemical plants, and electrified railways.
- High-Voltage Networks: 35KV transmission lines and capacitor bank protection.
Why Choose Our Reactors?
- All-Weather Reliability: Operates in -25°C to +50°C with anti-UV coatings.
- Modular Design: Combine with hollow capacitors for scalable current limiting solutions.
- Zero Maintenance: Dry-type construction eliminates coolant leaks.
- Global Certifications: Complies with IEC, IEEE, and ANSI standards.
Operating Conditions
- Altitude: ≤1000m (Higher elevations available on request).
- Temperature: -25°C to +45°C (Extended range optional).
- Humidity: ≤95% RH (Non-condensing).
- Environment: Resists salt spray, dust, and industrial pollutants.